Product description castle series 1KVA 6KVA ~ UPS Rack, the use of double conversion of the pure line of the structure, is effective to solve all power problems of the reliable structure design. The architecture can effectively block the impact of abnormal power supply to the load, and ensure the stability of the output power, precision and reliability, so that the load safe operation. Especially for the rack application design, suitable for protecting rack servers, storage rack network equipment products etc.. Rack C series (1kVA~6kVA)
Sinusoidal output of the technical parameters in the power mode or battery mode, can output low distortion sine wave power supply for the user's load equipment for reliable power supply. When the switching time of power cut or complex, UPS switches between power mode and battery mode is no conversion time, effectively guarantee the reliability of load operation. Rack UPS 1K~3K (S) with zero line of fire detection function. , avoid UPS city power input zero line of fire. Bypass output of human nature in order to avoid the use of UPS users to make BYPASS work in MODE is not on the use, causing the city's power outages, UPS and equipment are abnormal shutdown. Santak UPS 1K~3K Rack (S) input normal market power, the default no bypass output. Must turn on, will have normal inverter output. But you can change the configuration of the WinPower2000 software through the Santak site on the site to bypass the output of a bypass". TVSS function is VOLTAGE SURGE SUPPRESS TRANSIENT wave voltage protection function. In UPS Rack is used for FAX, TELEPHONE, MODEM, network and other conversion protection functions. Input power due to the modified UPS Rack with input power due to the correction function, in full load, the input power can reach more than 0.95, the user's power grid environment will not be polluted. The UPS Rack can be used to direct the battery to make the UPS Rack to use more convenient and reliable in the power outage state of the city. Bypass protection bypass power supply function to make the UPS Rack emergency handling capacity greatly enhanced, while the user's load equipment has special requirements, such as voltage can not be too high, UPS Rack provide bypass power supply voltage is too high, the use of the load equipment from high pressure. Auto start function when the city is abnormal, access to the battery mode until the end, UPS Rack will be shut down, when the city is back to normal, UPS Rack will automatically start the boot, restore normal power supply, without the need for users to start one by one. Long term power supply design UPS Rack provides users with a comprehensive and long-term choice. To configure the appropriate battery pack, you can use the time of the user's discharge to use up to 8 hours, to meet the requirements of different power grid environment. Long - term machine powerful charging capacity of UPS Rack long - term machine in addition to the discharge time, the battery back charge capacity is also very strong, can provide about 4 ~ 9A of the initial charge current. Self check function UPS Rack can simulate the situation of power, enter the battery mode power supply, this feature can be performed either by the self-test button on the panel, or with Santak monitoring software, in a regular or irregular way. Strong anti jamming against electromagnetic interference and radio frequency interference, Rack UPS EN500912 follow international standards and IEC61000-4 series standard design, effectively improve the safety and reliability of using UPS. The wide range of input voltage and frequency can be used by collocation generator to make the UPS Rack can be used with the main brand generator, the use of time is much longer, and the power of generator is effectively removed. Inductive load UPS Rack can be connected with inductive load (pf=0.8). Customers such as other special needs, can be directly linked to Santak. Site free download WinPower2000 monitoring software in order to use the user for the management of UPS more convenient and effective, on the Santak website can download the WinPower2000 network version of the software, to achieve intelligent management. Equipped with Slot Intelligent smart socket UPS Rack with a Slot Intelligent smart slot, the user can choose Santak AS400 card, to provide AS400 IBM standard communication signal, the user uses AS400 interface to make Display Remote, including sound alarm and light display. Or buy Santak WebPower smart card, through the Internet international Internet management, or through SNMP network management, to achieve centralized monitoring and remote monitoring and other functions. The standard battery pack UPS Rack is configured for the same size as the standard battery pack (for customer selection). In addition to the requirements of C2KR, C3KR, C6KR standard battery pack a set of standard battery pack, but also for C1KRS, C6KRS long term machine configuration of more than 2 sets of standard battery packs, and C2KRS, C3KRS long term machine configuration of more than 3 standard battery pack. Standard battery pack uses high quality of the original factory Panasonic battery, with good battery quality, ensure the use of UPS security and reliability.
|