Santak UPS power supply installation notes |
Time:2017-04-13 Source: Views:5122 |
Santak 1 UPS power line connection method and precautions
The input socket of the Santak UPS power supply is connected with the power supply, and the output socket can be connected with the computer and the monitor through the wiring board. For Santak UPS power supply, the output power is divided into two parts: one part is the voltage and battery output, is used to connect the host computer; the other part is used for display in the regulated output voltage instability regions, printers and other equipment.
Note: the battery voltage and output socket output socket and APC Santak of the power supply is not allowed to access the printer equipment, UPS power output is not allowed to access all of the electric drill, electric hammer and electric fan. UPS power outlet can not be directly connected to the input socket. The UPS power supply load should not exceed 80% of the rated load.
2 Santak UPS power supply host internal battery
Internal UPS power supply host has a battery, its role is to provide power for the control of its internal battery, the power loss caused by the host to start is not normal, such as relay can be closed, no power output socket.
3 Santak UPS power supply normal indication status
The correspondence and the meaning of the indicator are described as follows:
A. city power has been connected, UPS power supply at the end of the boot: green 1[power and load / power 5 lights. Green 1 lights indicate a power input. This is the 2 yellow lights should bypass indicator, is not directly regulated by the process of electricity to power the device from the bypass, but the 2 UPS power we currently use no bypass function, 2 yellow light is not significant.
B. boot power: press the ON switch button in the boot flash, 1 green, 2 yellow, the load / battery and fault indicator light at the same time, then the load / battery, fault indication lights from the first one by one, the load / battery 5 lamps to light; about 3S after the 2 yellow lights, green 2[inverter. Light output socket of power supply, UPS power supply into a normal power state. At this time the load / battery light indicates the load of the load, the maximum load to maintain the load / battery 1 lights are not bright, see table 1.
C. battery power supply without power supply:
When the power cut, the green lamp extinguished, no electricity, 1 yellow lights, said the battery power supply, the load / battery capacity battery lamp current, and alarm. Battery capacity enough, alarm sound long time interval and the load / battery lights much; battery capacity is insufficient, the alarm sound to shorten the time interval, the load / battery lights less; when the load / battery 1 lights, said battery only less than 25% of the energy [see table 1], the alarm sound very short, that can not continue to supply, other measures should be taken.
When using the generator power supply and power recovery, the green 1 lights, yellow, the 1 lights out, the alarm stopped, the load / battery light load.
The D. is powered off: press OFF button, 2 green lights, output power, load / battery, fault indicator light, then the load / battery, fault indicator goes out from the bottom of one by one, and finally the load / battery 5 lamps to light, green light 1 remain lit UPS power to stop working, keep the battery state of charge.
4 battery charging and discharging requirements
Battery capacity and the length of time is the main basis for measuring the performance of Santak UPS power supply, so the correct use and maintenance of batteries is very important. Therefore, we require the battery to charge and discharge on a regular basis, because the long-term charge will lead to the aging of the battery plate, discharge capacity decreased. However, the problem of insufficient capacity can also be caused by the long time charging. Its judgment criteria are: continuous charging time less than 16h and is in a state of discharge, in case of such a situation in a timely manner with the generator power supply while charging.
|
|