How to extend the service life of the Santak UPS power supply in Shenzhen
Time:2016-01-12    Source:    Views:3386
Normally, the service life of Santak UPS power supply can generally be 8 to 10 years, and the maintenance of proper UPS power supply which can be used for more than 15 years, as in many parts of the United States data center are used 20 years, the inside of the UPS power supply has never been replaced. This and the power of the core elements of the battery has a great relationship, the following we have to introduce the maintenance of Santak UPS power supply in Shenzhen and how to extend the life of the power supply. Santak UPS power to maintain the perfect maintenance conditions are: Santak UPS room should be air-conditioned and anti-static floor of the room, lightning effect is better, to dust, moisture, sunscreen. Input voltage is best within the design range, the most reasonable range of load is 30%-60%, full load, overload use will affect the life of Santak UPS. Should be maintained at least once a year. But in reality we generally difficult to achieve so considerate, so some ups power supply maintenance tips is particularly important, such as to prevent the accumulation of dust inside the chassis, regular maintenance of the power supply inside the battery and so on. These maintenance tips tend to greatly extend the service life of the UPS power supply, reduce the trouble of maintenance. Extend the Santak UPS power life of the method to extend the Santak power life of the method has a lot of, which is the main and inside the battery has a relationship, following the introduction of a few simple tips. 1, avoid and inductive load connection. Inductive load current flow is large, usually 3 of the rated current, 4 times or so, if the UPS and inductive load connection, will instantly cause the power overload, affect the power battery life. In the life of the common load inductance have electric fans, refrigerators, washing machine etc.. 2, try not to overload operation. As far as possible in the range of less than the rated power, because the overload power operation will not only affect the life of the load, but also the power supply of UPS power supply to the impact of life. In general, the load of the on-line UPS power should be controlled in 80% ~ 70%, and then the load of the UPS power supply should be controlled in 70% ~ 60%. Note that excessive light load is not good, although it is not as serious as overload. 3, regular maintenance. This is to be aimed at Santak UPS power supply inside the battery, as the core components of UPS power supply, we should carefully protected, periodic maintenance, if not long-term local power outage must be on a regular basis (three months) man-made interruption of power supply and make ups of Santak load discharge. Because no long-term power had been broken, so you always thought it is in normal work, and actually once the power is turned off, it can only provide a short delay or no delay, reason is the ups battery in long-term floating charge state.
LinkUrl:
Add:Chaoyang District Wangjing Beijing garden building 25, 6032  Tel:400-168-5636    
CopyRight © 2025 Partner of Sante series products in China  All rights reserved